On-site installation guide (UL)

Please regard this information when installing the Node.

Installation specifications

Node 400

Node 1000

Node 2000

E-File number

E506869

Rating in Volt

12-48 V

Rating in Ampere

13.2 A RMS

33 A RMS

66 A RMS

Short circuit current rating

5k A

Maximum Surrounding Air Temperature

40° C

Torque Values for Terminal screws

0.5 - 0.6 Nm (4.4 lbf∙in)

Short circuit rating and fuse type

Listed Class T Fuse, rated min. 160Vdc 50A 20kA. (JDDZ/7.E81895)

Temperature rating of field installed conductors >85°

N/A

Branch fuse required

SOMANET servo drives don’t have a fuse on-board, so a branch fuse is required as a protection.

The following fuse has been tested and approved by UL according to the requirements of UL 61800-5-1:

Manufacturer

Littelfuse

Product designation

JLLN050.T

CCN

JDDZ/7

Class

T

Cat. No.

JLLN, 558

VAC

300V

VDC

160V

Interrupt Rating (IR)

20kA (@160Vdc)

I nominal

50A

Field wiring terminal marking

../../../../_images/e1_terminal_designation.png

Attention

These products are intended for operation within circuits not connected directly to the supply mains (galvanically isolated from the supply, i.e. on transformer secondary).

Attention

Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.

Attention

CSA: For Canada:
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the Canadian Electrical Code, part I.

Attention

Operation of this equipment requires detailed installation and operation instructions provided in the Installation/Operation manual intended for use with this product. This information is provided online at www.doc.synapticon.com and can be downloaded as PDF.

A hard copy of this information may be ordered at +49 7031 / 30 478 -0

L’utilisation de cet appareil nécessite des instructions détaillées d’installation et de fonctionnement fournies dans le manuel d’installation/utilisation prévu pour ce produit. Cette information est disponible en ligne sur www.doc.synapticon.com et peut être téléchargée sous forme PDF.

La version papier peut être commandée au +49 7031 / 30 478 -0

Note

Motor overtemperature sensing is not provided and must be provided in the field.