- Hardware Manuals
- Commissioning and Tuning Guide
- Software Reference
- Resources
Please regard this information when installing the Node.
Installation specifications |
Node 400 |
Node 1000 |
Node 2000 |
---|---|---|---|
E-File number |
E506869 |
||
Rating in Volt |
12-48 V |
||
Rating in Ampere |
13.2 A RMS |
33 A RMS |
66 A RMS |
Short circuit current rating |
5k A |
||
Maximum Surrounding Air Temperature |
40° C |
||
Torque Values for Terminal screws |
0.5 - 0.6 Nm (4.4 lbf∙in) |
||
Short circuit rating and fuse type |
Listed Class T Fuse, rated min. 160Vdc 50A 20kA. (JDDZ/7.E81895) |
||
Temperature rating of field installed conductors >85° |
N/A |
SOMANET servo drives don’t have a fuse on-board, so a branch fuse is required as a protection.
The following fuse has been tested and approved by UL according to the requirements of UL 61800-5-1:
Manufacturer |
Littelfuse |
Product designation |
JLLN050.T |
CCN |
JDDZ/7 |
Class |
T |
Cat. No. |
JLLN, 558 |
VAC |
300V |
VDC |
160V |
Interrupt Rating (IR) |
20kA (@160Vdc) |
I nominal |
50A |
Attention
These products are intended for operation within circuits not connected directly to the supply mains (galvanically isolated from the supply, i.e. on transformer secondary).
Attention
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.
Attention
Attention
Note
Motor overtemperature sensing is not provided and must be provided in the field.