0x2006 Protection

CAUTION! Every Drive module has internal over-current, over-voltage, under-voltage and temperature protections to protect itself. If a different set of protection values is needed, this can be set to custom values. Use this feature carefully!

Name Index:Sub Type Bit Size Min Data Max Data Default Data Unit Access PDO Mapping
Undervoltage setpoint 0x2006:1 DINT 32 0 V readwrite

Custom value for undervoltage protection.

Name Index:Sub Type Bit Size Min Data Max Data Default Data Unit Access PDO Mapping
Overvoltage setpoint 0x2006:2 DINT 32 1 V readwrite

Custom value for overvoltage protection.

Name Index:Sub Type Bit Size Min Data Max Data Default Data Unit Access PDO Mapping
Overcurrent setpoint 0x2006:3 DINT 32 1 mA readwrite

Custom value for overcurrent protection.