0x605A Quick stop option code

Indicates what action is performed when the quick stop function is executed. The slow down ramp is the deceleration value of the used mode of operations. The table below shows the value defenitions for the function.

Value Definition
0 Disable drive function
2 Slow down on quick stop ramp and transit into switch on disabled
6 Slow down on quick stop ramp and stay in quick stop active
Name Index:Sub Type Bit Size Options Unit Access PDO Mapping
Quick stop option code 0x605A:0 UINT 16
Disable Drive Function 0
Slow down on quick stop ramp and transit into switch on disabled 2
Slow down on quick stop ramp and stay in quick stop active 6
readwrite